Trap Priming Valves and Electronic Hot Water Flushing Systems

mr-500a.jpg

MRA-500 Trap Primer

Product Code:

80102

Product Description:

Primes 1-10 traps as little as a 21 kPa pressure drop is needed for our MRA500 primer to function.

Fact: Other brand needs a pressure drop of 35 kPa before it works.Minimum line pressure of 140 kPa – max 560 kPa.

Fact: Other brand can only work in a more limited pressure range of 245 kPa to 525 kPa.

  • No adjustments required – cartridge tube has a partition moulded in place which determines amount of water discharged from the primer. Other brands have primers that require adjustments to deliver different discharge amounts

  • No air pre-charge required – can be disassembled in the field for cleaning and repair and then put back together.

  • Other brand has an air pre-charge that once lost, the product cannot be used.Fully serviceableReplaceable sediment filter and servicing

  • Inter-changeable cartridge tubesFour view holes (air gaps) for easy inspection of performance

  • Distribution Units available, serving up to 10 floor drain taps (Model 80105 – MI-DU)

  • WaterMark approved

MRA-500-A Adjustable.png

MRA-500-A Adjustable Trap Seal Primer

Product Code:

80102A

Product Description:

MIFAB model MRA-500-A Adjustable Trap Seal Primer, with 15 mm male BSP inlet and 15mm BSP female outlet. Complete with air gap with four viewing holes and removable filter screen.

ts distribution unit.png

Trap Priming Distribution Units

Product Description:

The MAG-MIFAB MI-DU Trap Seal Primer Distribution Unit can be installed underneath pressure drop activated trap seal primers to distribute water to up to ten floor drain traps that are near each other.

Example application: when a men and women’s restroom are located side by side with a common pipe chase between them – so one trap seal primer with a distribution unit dialed to the 2 setting can service both floor drain traps.

Continuous Flow Trap Priming Valve.png

Continuous Flow Trap Priming Valve

Product Code:

MI-TSP2

Product Description:

‘Original’ style of trap seal primers

  • Brass body with a neoprene rubber poppet float on the inside that rises upward as water flows through primer

  • When the poppet rises off its seat, water flows from the primer, through the plumbing line connection and into the floor drain trap

  • Discharges larger amounts of water – needed when water pipes are larger and need a “flow through” or “continuous flow” instead of smaller drops of water

  • Increased water flow ensures a complete flow cycle through pipes

  • Fully serviceableTwo view holes/air gaps for easy inspection of performance

  • MIFAB TSP-2 has threaded connections to be installed in a vertical position within the horizontal water supply line

  • WaterMark approved

 

38003 MAG Electronic Single Trap Priming System.jpg

Electronic Trap Priming System

Product Code:

38003

Product Description:

  • Automatically maintain a constant water seal in floor drain traps

  • Various models available: single or multi points, lockable cabinet option

  • Primes 1-10 traps

  • Available as a pre-plumbed/pre-assembled, programmed electronic system

  • Designed and engineered at MAG’s Australian factory with an approved vacuum breaker, 24 volt solenoid valve operated by a timer, adjustable flush times, shut off valve for maintenance and a manifold system to distribute water evenly to floor drain traps

  • Timer control with manual override to adjust frequency and amount of water

  • Ideal for factories, industrial plants, food outlets, commercial businesses, schools, hospitals, manufacturing and any other buildings requiring floor drain trap seal protection

  • Working pressure min. 100 kPa, max. 600 kPa

  • Primary assembly to be mounted min. 300mm above finished floor or ceiling space

  • Available in lockable cabinet (Model: 38010 Steel Cabinet with slot lock; Model: 38011 Stainless Steel Cabinet with key lock)

38001 MAG Electronic Hot Waster Flushing System.jpg

Electronic Hot Water Flushing System

Product Code:

38001

Product Description:

  • Automatically flushes hot water down waste pipes to prevent grease build up

  • Suitable for cold water flushing also

  • Model 38001 MAG Electronic Hot Water Flushing System

  • Available in lockable cabinet (Model 38002 Steel Cabinet with slot lock; Model 38012 Stainless Steel Cabinet with key lock)

  • 24 hour timer control with manual override

  • Timing function – adjustable to suit, as per selection made

  • Inlet and outlet 12mm copper pipe, 24 volt solenoid valve

  • Working pressure min. 100 kPa, max. 600 kPa

  • Primary assembly to be mounted min. 300mm above finished floor

Trap Priming Valves and Electronic Hot Water Flushing Systems

Choose from 3 types of Trap Priming Systems: Pressure drop activated, Continuous flow and Electronic Trap Seal Primers.

The MAG-MIFAB Pressure drop activated trap primer (MRA500) offers these key benefits:

  • Activated with a pressure drop as little as 21 kPaNo air pre-charge requiredMinimum line pressure of 140kPA-max 560kPaFully Serviceable

  • No adjustments requiredReplaceable sediment filter and servicing

  • Inter-changeable cartridge tubesFourview holes (air gaps) for easy inspection of performance

  • Distribution Units available, serving up to 10 floor drain taps

  • WaterMark approved

The MIFAB TSP-2 Series Continuous flow primer discharges larger amounts of water when water pipes are larger and need a complete flow cycle through the pipes – a “continuous flow” instead of smaller drops of water.

MAG’s Electronic trap seal primers automatically maintain the water seal of floor drain traps and are available as a pre-assembled, programmed electronic system. Also available is our Hot Water Flushing System which automatically flushes hot water (or cold water) down waste pipes to prevent grease build up.